Super practical PCB circuit board design questions and answers summary
Friends often ask questions about PCB circuit board design. Today, the editor of Wangshen Circuit Board Factory made a summary of your questions, and compiled the answers of technical engineers as follows, for reference only:
1. Why the final PCB layout drawing does not match the schematic
Answer: This situation can easily happen. Indeed, it is obviously connected on the schematic diagram, because the drawing line does not meet the specifications. As a result, they are not connected in the generated netlist.
2. There are a lot of previous file lists in the toolbar, which are very long and messy. I deleted the original file. May I ask where I can delete it.
Answer: There is a Protel configuration file Client99.ini in the \Windows directory. You can open it with a text editor, find the [Closed Files List] column, delete all the content belonging to this column, save it and exit.
3. Why the diodes and transistors in the schematic diagram cannot find the pins in the PCB circuit board network table loading
Answer: The reason is that the pin name definitions in SCH and PCB circuit boards are different. Especially the A, K-1, 2 and E, B, C-1, 2, 3 of the diode and transistor, change the network table by yourself, don't make a mistake in the pin order.
4. How to find the hidden DESIGNOR component number in protel99
Answer: In SCH, double-click the component, select Hidden Fields and Field Names in the dialog box, and then double-click the serial number Text and the parameter Type respectively to uncheck Hide. Finally, double-click the component, and uncheck Hidden Fields and Field Names in the dialog box.
5. How to use "global function" in protel99 to encapsulate all the unpackaged components
Answer: Press the Global button, for example: To change the package of Res2, remove * in Desigator, fill in Res2, tick the Footprint of Copy Attribute, and select All primitives in Change Scope
6. When PROTEL99 was installed, it was not asked to enter LICENSE NUMBER. Now PROTEL99 can be used, but there are problems. How to enter LICENSE NUMBER?
Answer: First of all, I suggest you reinstall protel99se. Your question: Click the arrow on the left of the menu bar of protel99, select secuity, select PCB SCH Route, click un-lock, press Add and fill in the password.
7. Compared with the SCH network table generated from the PCB circuit board, what command is used and how to compare?
Answer: First, open the PCB document, select the design-netlist manager menu, press the lower left Menu button, and select Create Netlist From Connected Copper..., a netlist will be generated. Save it.
Then, in the design-netlist manager menu, press the lower left Menu button, select Compare Netlist, select your SCH netlist, OK, select the PCB circuit board netlist you just saved. A comparison file will be generated later. The two are the same It's OK.
Contact: Ms Tracy
Phone: 0086 18682010757
Tel: 0086 18682010757
Add: BludingA,Shixiaganglian Industrial Park,Shajing,Baoan,Shenzhen,China